Display: True RMS; accuracy guarantee range: 10~100% of range; in case of open circuit, less than 50 characters may be allowed for residual
reading. AC crest factor: Up to 3.0 for full scale Nonsinusoidal waveform: The accuracy for crest factor of 1.0~2.0 shall be increased by 3.0%.
The accuracy for crest factor of 2.0~2.5 shall be increased by 5.0%.
The accuracy for crest factor of 2.5~3.0 shall be increased by 7.0%.
5. Resistance/admittance measurement
Range
600.00Ω
6.0000kΩ
60.000kΩ
600.00kΩ
6.0000MΩ
60.000MΩ
60.00nS
6. Capacitance measurement
Range
6.000nF
60.00nF~600.0μF
6.000mF~60.00mF
- 50 -
03075/03079
Resolution
Accuracy, ± (a%reading + b number of characters)
0.01Ω
0.1Ω
10Ω
100Ω
1kΩ
0.01nS
Resolution
Accuracy, ± (a%reading + b number of characters)
1pF
10pF~100nF
1μF~10μF
±(0.05%+10)
±(0.05%+2)
±(0.05%+2)
±(0.05%+2)
±(0.15%+5)
±(3%+2)
±(1%+10)
±(3.0%+30)
±(2.5%+5)
±10%