a) Power loss
Cause:
Action:
Signal:
Reset:
Possible reasons:
b) Current error
Cause:
Action:
Signal:
Reset:
Possible reasons:
c) Current error state
Cause:
Action:
Signal:
Reset:
Possible reasons:
d) One Hall error state
Cause:
Action:
Signal:
Reset:
Possible reasons:
e) Hall error state
Cause:
Action:
Signal:
Reset:
Possible reasons:
www.praher-plastics.com
The power supply has been interrupted
When the Aquastar is at an unsafe position it approaches filter if the main
supply is back.
1s
Connect power.
Power loss. Cable break
The permitted motor current has been exceeded
The motor stops. After two seconds the Aquastar retries to reach position
3s
No need to reset. If current is below current-limit in the next attempt,
normal operation goes on
Aquastar is not enough fixed to the valve
The permitted motor current has been exceeded three times in this
position cycle
Aquastar is set to errorstate. No possible actions until Aquastar is reset
4s
Press "ON" and "OFF" Button simultaneously for at least 5s
Aquastar I not enough fixed to the valve. Motor is broken. Valve is broken.
Pump has not been turned off. Water column of 3 meter exceeded.
Chosen position has not been reached within 3 minutes or 3 rounds.
Aquastar is set to errorstate. No possible actions until Aquastar is reset
5s
Press "ON" and "OFF" Button simultaneously for at least 5s
Defective electronics
Motor has been turned on but no position change for 30 seconds
Aquastar is set to errorstate. No possible actions until Aquastar is reset
6s
Press "ON" and "OFF" Button simultaneously for at least 5s
Defective electronics. Insufficient power supply. Motor is broken. End pos.
switch is not connected. Motor is not connected.
21