Herunterladen Inhalt Inhalt Diese Seite drucken

Trouble Shooting Esc Brushless - Carson X8E Specter Brushless 4S Betriebsanleitung

X8eb chassis
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Trouble Shooting ESC Brushless

Trouble
after power on, motor doesn't work
after power on, motor doesn't work, but
G
emits "beep-beep-, beep-beep-" alert
tones
(every group of "beep-beep-" has a time
interval of 1 second)
after power on, red Led always lights, the
motor doesn't work
The motor runs in the opposite direction
when it is accelerated
The motor suddenly stops running
When accelerating quickly, the motor
stops or trembles
44
CARSON X8E Chassis 500409015 / 500409016
possible reason
The connections between battery pack and
ESC are not correct
Input voltage is abnormal, too high or too
low
Throttle signal is abnormal
The wire connections between ESC and the
motor are not correct
The throttle signal is lost
The ESC has entered the "Low voltage protec-
tion mode" or "Over-heat protection mode"
The battery has a bad discharge performance Use a better battery
The "Start mode (Punch)" of the ESC is too
aggressive
solution
Check the power connections Replace the
connectors
Überprüfen Sie die Einstellung für die Batte-
Check the adjustment of the voltage of the
battery pack
Plug the receiver wire into the throttle chan-
nel of the receiver correctly
Swap any two wire connections between the
ESC and the motor
Check the transmitter and the receiver
Red LED flashing means "Low voltage protec-
tion". Please replace battery pack.
Green LED flashing means "Over-heat protec-
tion", please stop running to cool the ESC.
Select a softer option for the "Start mode
(Punch)"