re g i ste r de s crip tion
ENErGy COUNTEr rECOrDING PArAMETEr BLOCK
Timestamp of the record block
+kWh1 • Phase 1 imported active energy
-kWh1 • Phase 1 exported active energy
+kWh2 • Phase 2 imported active energy
-kWh2 • Phase 2 exported active energy
+kWh3 • Phase 3 imported active energy
-kWh3 • Phase 3 exported active energy
+kWh∑ • System imported active energy
-kWh∑ • System exported active energy
kWh∑BAL • Balance of system active energy (imp-exp)
+kVAh1-C • Phase 1 imported capacitive apparent energy
-kVAh1-C • Phase 1 exported capacitive apparent energy
+kVAh1-L • Phase 1 imported inductive apparent energy
-kVAh1-L • Phase 1 exported inductive apparent energy
+kVAh1 • Phase 1 imported apparent energy
-kVAh1 • Phase 1 exported apparent energy
+kVAh2-C • Phase 2 imported capacitive apparent energy
-kVAh2-C • Phase 2 exported capacitive apparent energy
+kVAh2-L • Phase 2 imported inductive apparent energy
-kVAh2-L • Phase 2 exported inductive apparent energy
+kVAh2 • Phase 2 imported apparent energy
-kVAh2 • Phase 2 exported apparent energy
+kVAh3-C • Phase 3 imported capacitive apparent energy
-kVAh3-C • Phase 3 exported capacitive apparent energy
+kVAh3-L • Phase 3 imported inductive apparent energy
-kVAh3-L • Phase 3 exported inductive apparent energy
+kVAh3 • Phase 3 imported apparent energy
-kVAh3 • Phase 3 exported apparent energy
+kVAh∑-C • System imported capacitive apparent energy
-kVAh∑-C • System exported capacitive apparent energy
+kVAh∑-L • System imported inductive apparent energy
-kVAh∑-L • System exported inductive apparent energy
+kVAh∑ • System imported apparent energy
-kVAh∑ • System exported apparent energy
kVAh∑BAL-C • Balance of system capacitive apparent en. (imp-exp)
kVAh∑BAL-L • Balance of system inductive apparent en. (imp-exp)
kVAh∑BAL • Balance of system apparent energy (imp-exp) (BAL-C + BAL-L)
+kvarh1-C • Phase 1 imported capacitive reactive energy
-kvarh1-C • Phase 1 exported capacitive reactive energy
+kvarh1-L • Phase 1 imported inductive reactive energy
-kvarh1-L • Phase 1 exported inductive reactive energy
+kvarh2-C • Phase 2 imported capacitive reactive energy
-kvarh2-C • Phase 2 exported capacitive reactive energy
+kvarh2-L • Phase 2 imported inductive reactive energy
-kvarh2-L • Phase 2 exported inductive reactive energy
+kvarh3-C • Phase 3 imported capacitive reactive energy
-kvarh3-C • Phase 3 exported capacitive reactive energy
Available only for instrument with separated Inductive and Capacitive apparent counters.
Available only for instrument with Total apparent counters (ind+cap).
84
Value format
words (IEEE)
UnixTime
2
0.1 Wh
2
0.1 Wh
2
0.1 Wh
2
0.1 Wh
2
0.1 Wh
2
0.1 Wh
2
0.1 Wh
2
0.1 Wh
2
0.1 Wh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 VAh
2
0.1 varh
2
0.1 varh
2
0.1 varh
2
0.1 varh
2
0.1 varh
2
0.1 varh
2
0.1 varh
2
0.1 varh
2
0.1 varh
2
0.1 varh
2
MODBUS rTU/ASCII, TCP