PROBLEM
The air conditioning
·
The air conditioning
unit works for a
short time only
·
The air conditioning
unit works, but does
not cool the room
CAUSE
no electricity
it is not plugged into the mains
the safety device has tripped
the safety float has tripped
the exhaust hose is blocked
there are bends in the exhaust hose
window open
there are heat sources in the room (burner,
lamp, etc)
the exhaust hose is detached
the air conditioning unit is not powerful enou-
gh for the conditions or size of the room
Particular odour in
air filters clogged
the room
The air conditioning
unit does not ope-
'
rate for about three
minutes after turning
it on
LT/FT/PF/Fl.
.
display The full indi-
cator light is on
the safety device has tripped
See "self-diagnosis" section
REMEDY
·
wait
plug into lhe mains
contact your service cenke
position the exhaust hose cor-
rectly
check there are no obstacles
obstructing air discharge
eliminate the bends
close the window
eliminate the heat source
connect the exhaust hose
clean or replace the filters
clean or replace the filters
wait for three minutes