Novy 1786-1 Montageanleitung Und Bedienungsanleitung Seite 58

Induktions kochfelder free zone
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CONNECTION OF THE HOB FOR 4 ZONES
Mains
230V~1P+N 50/60Hz
400V~2P+N 50/60Hz 2 Phases + N
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
CONNECTION OF THE HOB FOR 5 ZONES
Mains
230V~1P+N 50/60Hz
400V~2P+N 50/60Hz 2 Phases + N
400V~3P+N 50/60Hz 3 Phases + N
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
3 x 2,5 mm²
4 x 1.5 mm²
Connection
Cable diameter
1 Phase + N
3 x 4 mm²
4 x 2.5 mm²
5 x 1.5 mm²
equipped with a faulty earth connection.
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
58
Protection calibre
25 A *
16 A *
Protection calibre
40 A *
25 A *
16 A *