• The safety unit and/or safety valve must be accessible.
• A sewer drain equipped with a gripper is necessary.
• The lower tapping connection allows the tanks to be completely drained.
• The tanks only work in vertical position.

3. Fitting magnesium PrOtectiOn On the uPPer Base

Model
500L
Height
1900
Height + riser
1985
blocks
Dimension of
rough anode
500
on upper base
Minimum fitting
2300
dimension
Minimum fitting
dimension +
2385
riser blocks

4. water cOnnectiOn

Before proceeding with the water connection, it is essential to clean the water-supply pipe
properly to avoid introducing metallic or other particles in the tank.
DTU Plomberie 60.1 additif 4 (NFP 40-201) must be followed.
When using copper piping, the connection on the hot water outlet must be made using
a dielectric connector or a cast iron sleeve so as to prevent any galvanic corrosion (iron
copper). Brass connectors are not allowed at this level (DTU 60.5). The installation of an
approved safety unit or set, valve and safety valve is compulsory.
If the inlet pressure of the network is ≥ 5 bar, a pressure reducer must be assembled starting
from the general distribution. We recommend a pressure of 3 to 4 bar. Check when hot that
the pressure does not exceed 6 bar.
Install an air bleeder on the tank upper connectors (sanitary hot water outlet).
To prevent the installation components (exchangers, valve, safety unit) getting clogged up
with sludge, it is compulsory to put a mesh filter on the general sanitary cold water supply
where the tank is located.
The sanitary hot water in the tanks can reach a high temperature. Therefore it is compulsory
to install a solar type thermostatic mixer faucet before the sanitary hot water distribution to
the draw-off points. The temperature order at the draw-off points must comply with legislation
in force.
When using piping made of COMPOSITE MATERIALS (PER, PVC, etc.) it is essential
!
to install a temperature limiter at the tank outlet adjusted according to the performance
of the material used.
recommendations: For areas with very hard water (Th>20°F), the use of a water softener
does not affect our warranty as long as the water softener complies with applicable standards
and is checked and serviced regularly (Decree No. 2001-1220 of 20 December 2001).
the hardness of the water must remain over 12°f.
02 / 2014
750L
900L
1000L 1000L
1935
2215
2460
1690
2020
2300
2545
1775
650
800
800
800
2485
2915
3160
2390
2570
3000
3245
2475
CORHYDRO / CORFLEX
1500L 1500L
2000L 2500L 2500L
TB
TB
2325
1695
2130
2410
1780
2215
1000
1000
600
3225
2595
2630
3310
2680
2715
3000L 3000L
TB
2490
1906
2915
2126
2575
1991
3000
2211
650
650
600
500
3040
2456
3415
2526
3125
2541
3500
2611