C 101
10° - 65°
Photometric
Typical values measured without wiremesh, with diffusing glass
Lamp : 220V, 3200K, biplane:
Light Levels (lux) and Field Ø(m)
Axial Intensity (Cd)
1200W
Angle
Distance (m)
Lux
8
1613
9
1274
10
1032
11
853
12
717
14
527
16
403
Light Distribution (Half Beam)
Min.Angle
Cd x 1000
Note
To convert Candelas into Lux, divide by the square of the distance (in m).
Fresnel and PC lens Spotlights
Data
1000W / 26000 lm
1200W / 30000 lm
Min. Angle
Max. Angle
103200
8300
10°
65°
Ø (m)
Lux
Ø (m)
1,4
130
10,2
1,6
102
11,5
1,8
83
12,7
1,9
69
14,0
2,1
58
15,3
2,5
42
17,8
2,8
32
20,4
1000 W
1200 W
Max.Angle
Cd x 1000
1000, 1200 & 2000 W
C 103
7° - 61°
Photometric
Typical values measured without wiremesh, with diffusing glass
Lamp : 220V, 3200K, biplane:
Light Levels (lux) and Field Ø(m)
Axial Intensity (Cd)
1200W
Angle
Lux
Distance (m)
6
10000
8
5625
10
3600
12
2500
14
1837
16
1406
18
1111
Light Distribution (Half Beam)
Cd x 1000
Min.Angle
Note
To convert Candelas into Lux, divide by the square of the distance (in m).
Data
1000W / 26000 lm
1200W / 30000 lm
Angle Min.
Angle Max.
360 000
12 000
61°
Ø (m)
Lux
Ø (m)
0,7
333
7,1
1,0
188
9,4
1,2
120
11,8
1,5
83
14,1
1,7
61
16,5
2,0
47
18,9
2,2
37
21,2
1200 W
1000 W
Max.Angle
Cd x 1000
P a g e 1 5