EN: Installation Sheet
Description
The power distribution board, model ATS1330, provides a
simple means of star connecting ATS bus devices. It is fitted
with a single protected input port and five paralleled output
ports, providing either the traditional power and comms or
power alone. It is a standard board size and provides a power
OK LED (Figure 2, item 8) for easy diagnosis.
The module has an incoming and outgoing data bus / power
connection to achieve i.e. a proper stub connection for an
Advisor Master bus reader.
Mounting location
The ATS1330 PCB (Figure 1) can be mounted in any Advisor
Master cabinet, which supports the size B board.
© 2012 UTC Fire & Security. All rights reserved
2
Connecting the ATS1330
Figure 2 legend
Item
Description
(1)
ATS control panel (Mains powered device)
(2)
TERM — termination link
(3)
GND — earthing link
(4)
Building earth
(5)
Remote arming station (RAS)
(6)
Shield connection between mains powered and non-mains
powered device(s)
(7)
4-door DGP (mains powered device)
(8)
Power OK LED
(9)
DGP (mains powered device i.e. ATS1201)
TERM link fitted on first and last devices on the LAN. In a "star"
wiring configuration the TERM link is only fitted on the devices
at the ends of the two longest LAN cable runs.
1 / 4
P/N 1077855 (ML) • REV A • ISS 17AUG12

Werbung

loading

Inhaltszusammenfassung für Interlogix ATS1330

  • Seite 1 Mounting location TERM link fitted on first and last devices on the LAN. In a "star" The ATS1330 PCB (Figure 1) can be mounted in any Advisor wiring configuration the TERM link is only fitted on the devices Master cabinet, which supports the size B board.
  • Seite 2 The shield of the data cable cannot be connected at Die Bus-Verbindungsplatine ATS1330 ermöglicht eine the ATS1330. In case of a non-mains powered device, the sternförmige Verdrahtung von ATS-Buskomponenten (RS485). shield should be connected to the shield of the nearest mains Die Platine verfügt über einen geschützten Eingangsport und...
  • Seite 3 Sie das Produkt an den gekennzeichneten Sammelstellen. Weitere Informationen hierzu finden Sie auf der folgenden Website: www.recyclethis.info. Kontaktinformationen www.utcfireandsecurity.com oder www.interlogix.com Kontaktinformationen für den Kundendienst finden Sie unter www.utcfssecurityproducts.de P/N 1077855 (ML) • REV A • ISS 17AUG12 3 / 4...
  • Seite 4 4 / 4 P/N 1077855 (ML) • REV A • ISS 17AUG12...