Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Of Two Or More Light Barriers; Timing Diagram - Cedes ELS 300 Bedienungsanleitung

Safety trough-beam sensor
Vorschau ausblenden Andere Handbücher für ELS 300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

ELS 300
5.3.

Installation of two or more light barriers

To avoid cross-talking effects, it is necessary to keep a minimum clearance between two systems. This clearance
depends on the operating range at which the systems are used. In the diagrams in Figure 5, the minimum
clearance for the different types is shown.
Clearance
Figure 5: Clearance in function of operating distance
5.4.

Timing diagram

Power supply Tx
State of light beam
Output Rx:
NPN/DO
PNP/LO
Output Rx:
NPN/LO
PNP/DO
Figure 6: Timing diagram
6
Downloaded from
www.Manualslib.com
Rx1
Tx1
Tx2
Rx2
Operating range
Operating range [m]
uninterrupted
uninterrupted
interrupted
t
t
t
ON
RI
RL
manuals search engine
Installation and operation manual
ELS 300 Narrow aperture
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0.00
0.2
0.4
Turn-on time t
Turn-off time t
Response time on interruption t
Response time on light t
t
OFF
www.cedes.com
Use not recommended,
because of crosstalking
0.6
0.8
1
Operating range [m]
Operating range [m]
ELS 300 N & NA
< 30 ms
ON
< 40 ms
OFF
< 20 ms
RI
< 20 ms
RL
© CEDES/October 2016
1.2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis