* Operating Modes. DSW1
1)
EXTERNAL:
- ON: enables the activation of the entry panel relay in response to a «call from panel» command (configured on
DWS2). This activation is additional to the activation of the BUS2 Relay.
In «call from panel» mode, when a call is made from the entry panel, in addition to activating the BUS2 Relay, the relay
on the panel from which the call was made is activated (the timing of the panel amplifier relay depends on the time
programmed on the panel itself).
- OFF: disables the entry panel relay's activation function.
In «call from panel» mode, when a call is made from the entry panel only the BUS2 relay is activated.
2)
ALL / PRG:
- ON (ALL): Any system device that sends a valid command (in accordance with that programmed on the DWS2)
activates the relay.
- OFF (PRG): The relay is only activated if the command received is valid and furthermore has been sent from a
device (telephone, monitor) on which the BUS2 address has been pre-programmed (setup).
The residential terminals are programmed with BUS2 addresses (call codes) ranging between 1 and 1999 (refer to the
«Residential Terminals» section). The BUS relay allows the programming of addresses with activation authorisation,
such that the BUS2 relay can be linked to one sole device or a group of devices.
To set up the addresses for all valid devices on the relay, follow the steps below:
1.- :Setup Relay Programming:
PRG
Led
Press the BUS2 relay's PRG button.
The red led lights up indicating that
it is in programming mode.
Repeat steps 1 and 2 to set up all the addresses on the relay.
- The BUS2 relay exits programming mode once an address has been programmed or once 65 seconds have elapsed
without an address having been entered.
- In programming mode, the relay does not respond to activation commands.
- To delete the list of programmed addresses when outside programming mode, press and hold the PRG button for 2
seconds (the led flashes 3 times to indicate that the records have been deleted).
3)
TOGGLE / TIMER:
- OFF: Timed Relay Activation: Programmable at between 1 and 600 seconds.
Following a valid activation command, the BUS2 relay will remain activated for the programmed time.
To programme the activation time follow the steps below:
1.- :Setup Relay Programming:
PRG
Led
Press the BUS2 relay's PRG button.
The red led lights up and flashes
indicating that it is in programming
mode.
- ON: Relay activation in bistable mode (converted).
2.- Address (Call Code) Allocation
Button Panels
Press the call button
linked to the device
(telephone/monitor) that
you wish to set up.
2.- Programme the activation time
Led
· SEC: Each press increases the activation time
by 1 second.
· 10xSEC: Each press increases the activation
time by 10 seconds.
The relay switches its status with every activation.
Keypad Panels
Using the keypad, enter the call
code linked to the device
(telephone/monitor) that you wish
to set up and press the bell button.
3.- Press PRG to exit
programming. The LED
will turn off.