Herunterladen Diese Seite drucken

Fermax BUS2 Handbuch Seite 8

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
B B B B B US2
B B B B B US2
US2
US2
US2
US2
US2
US2
US2
US2
BUS2 Relay Operation and Configuration
* Activation Modes. Commands. DSW2
The first aspect to be configured is the activation mode, which indicates the conditions under which the BUS2 relay
will activate. This may be a command generated by a system device (telephone, monitor or panel) or via an external
contact.
External Contact:
- Relay Activation:
The relay is activated following a short circuit between the ACT/EXT and GND terminals via an external
element (wire switch ...etc).
This is an additional activation and is independent to the command based activation. There should be no
command configured to ensure the external contact is the only activation method.
- Disabling the Relay:
When there is a short circuit between the DISABLE and GND terminals, the BUS2 relay is disabled. It
does not respond to external activation commands, and remains at minimum consumption levels.
To re-enable the relay open the DISABLE-GND contact.
Data Command Activation:
Based on the DSW2's configuration the device will respond to the following commands (activated via the
telephone, monitor or panel).
Only one command can be selected.
DSW1 DSW2
DSW2 CONFIGURATION
1
2
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
(1) The BUS2 relay is activated if the command generated by a device agrees with that configured on the BUS2
relay.
The BUS2 relay can be configured to respond to commands from all the devices or just from certain ones. This
operating mode is configured via the DSW1.
(2) Panel Relay: panel amplifier relay that generates the call.
If the «Call from Panel» command is selected and the «EXTERNAL» option on the DSW1 switch is set to ON, the
BUS2 relay and the panel relay will be activated when a call is received from the panel.
Pag. 8
COMMAND
Function to be carried out by the
3
corresponding device
ON
Call to guard unit
OFF
Auto-start
ON
F1 Activation
OFF
F2 Activation
Lock-Release
ON
(following a call from the secondary panel)
Lock-Release
OFF
(following a call from the main panel)
ON
Call from Panel
OFF
Commands Disabled
DSW1
1
2
3
Command Activated RELAYS
(1)
BUS 2 RELAY
X
X
X
X
X
X
X
X
DSW2
1
2
3
COMMANDS
Panel RELAY
(2)
X

Werbung

loading

Diese Anleitung auch für:

3247