Expected service life
: 5 years
Key to symbols
: Type BF applied part
: Class II equipment
: Refer to instruction manual/booklet.
: Keep dry
: The used electrical and electronic products are not
household waste. Follow your national/local recycling
rules to dispose of them properly. In the EU countries,
please refer to waste management symbol s marked on
the package or the instrument.
P R E C A U T I O N S A N D C O N T R A I N D I C A T I O N S
Do not use this product without consultation with your doctor if you are under
dialysis therapy or on anticoagulants, antiplatelets or steroids. Use of this instrument
under such conditions could cause internal bleeding.
For specific information on your blood pressure, contact your physician. Never make
any judgment on your own regarding measurement results.
Do not use this product along with implantable and wearable medical electrical
equipment such as pacemaker, defibrillator, or electrocardiographic monitor. This
product is not also intended to be used with HF surgical equipment.
Do not use this product in an explosive environment such as near flammable
anesthetics or inside oxygen chamber.
The system may fail to yield specified measurement accuracy if operated or stored
in temperature or humidity conditions outside the limits stated in the specifications
section of this manual.
Do not use cuffs or accessories other than those specified by the manufacturer.
Otherwise, correct measurement readings cannot be obtained.
Use of this product in areas near mobile phones, microwave ovens or other devices
*Accuracy is guaranteed with the measured values that are within the measuring range.
This device complies with N1060-1:1995 A2:2009 Non-invasive sphygmomanometers
art
1:
General
re uirements
sphygmomanometers Part 3: Supplementary requirements for electro-mechanical blood
pressure measuring system.
The measurement accuracy of the product has been proven according to IS 81060-2
protocol. In the clinical study, K5 was used for the determination of diastolic pressure
values at all auscultatory measurements.
• This product is intended for use in the environment with one atmospheric pressure.
Speci cations are subject to change without notice due to improvements in performance.
with strong electromagnetic field may cause malfunctions.
Do not apply the cuff over wounded arm, arm under an intravascular access or
therapy or an arterio-venous shunt, or arm on the side of a mastectomy or lymph
node clearance. Otherwise injury may be resulted.
Make sure that inflation of the cuff is not causing prolonged impairment of blood
circulation. Also, be cautious about temporary loss of the functions of any other
medical equipment if any monitoring equipment is used on the same limb with the
blood pressure measuring cuff.
To avoid harmful injury due to interfered blood flow from cuff inflation,
- Make sure that AIR HOSE is not kinking before measurement. Otherwise, cuff
inflation may not be conducted properly and prolonged, and
- Do not make measurements repeatedly.
To avoid any possibility of accidental strangulation, keep this product away from
children and do not drape AIR HOSE around your neck.
Because the product includes precision parts, avoid extreme temperature variations,
humidity, shock, dust, lint, and direct sunlight. Do not drop or strike the product.
-5-