Herunterladen Inhalt Inhalt Diese Seite drucken

Cognex In-Sight 8000 Serie Handbuch Seite 19

Vorschau ausblenden Andere Handbücher für In-Sight 8000 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 105
8405 Vision System Specifications
Specifications
Power
Class 2 Power over Ethernet (PoE) device.
Power Type
PoE Type A and Type B.
Power
6.49 W maximum per Class 2 PoE.
Consumption
Current
Per Class 2 PoE requirements.
Voltage
48VDC nominal, applied from a Class 2 PoE source, which is typically powered from some
other voltage.
Case
0°C to 50°C (32°F to 122°F)
1
Temperature
Storage
-20°C to 80°C (-4°F to 176°F)
Temperature
Humidity
< 80% non-condensing
Protection
IP30 with cables and lens attached.
Shock (Shipping
IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z) axis) 80 Gs (800m/s
and Storage)
at 11ms, half-sinusoidal)
Vibration (Shipping
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to 500
and Storage)
Hz at 100m/s
1
To verify case temperature, use the EV GetSystemConfig("Internal.Temperature") Extended Native Mode
command or GetSystemConfig("Internal.Temperature") spreadsheet function. When issued, it returns the vision
system's internal temperature in degrees Celsius, which is ±5 degrees above the vision system case temperature.
®
Refer to the In-Sight
Explorer Help file for more information.Additional cooling measures are required if the case
temperature cannot be kept below 50°C. Examples of such measures include: mounting the vision system to a heat
sink using the M3 mounting screws, reducing the ambient temperature and ensuring there is air flow over the vision
system.
Note: The In-Sight 8100, 8200 and 8400 series vision system must be connected to
a Class 0, 2, 3 or 4 PoE power source, rated for at least 6.49 Watts.
2
/ 15mm)
18
8405
2

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis