Install the Mounting Bracket (BKT-IS8K-01)
Note:
When attaching the 8100, 8200, or 8400 series vision system to the
l
mounting bracket, use the M3 screws supplied with the mounting kit.
When attaching the 8505P vision system to the mounting bracket, use
l
M3x8mm socket head screws.
If using the 1/4-20 or M6 mounting holes, the thread length of the
l
screw should not exceed 8mm.
CAUTION:
It is recommended that the vision system be grounded, either by
mounting the vision system to a fixture that is electrically grounded or by
attaching a wire from the vision system's mounting fixture to frame ground or
Earth ground.
1. Align the mounting bracket with the mounting holes on the vision system.
2. Insert the M3 screws into the mounting holes and tighten using a 2.5mm hex
wrench. The maximum torque is 0.3 Nm (2.5 in-lb).
Install the Lens
1. Remove the protective film covering the threaded lens opening, if present.
2. Attach a C-Mount lens to the vision system. The exact lens focal length
needed depends on the working distance and the field of view required for
your machine vision application.