Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Service; Maintenance And Cleaning; Accessories/Spare Parts - Bosch BL 2L Professional Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
OBJ_BUCH-186-003.book Page 20 Monday, October 1, 2007 12:30 PM
20 | English
Work Examples (see figures E–I)
Note: For all work examples, with the exception
of figure I, it is assumed that the automatic
levelling is switched on.
Laying Flooring Plates at a 45° Angle
(see figure G)
Position the measuring tool via the tripod mount
5 onto the pin 15 of the alignment plate. Posi-
tion it in such a manner on the centred protru-
sion of the alignment plate 11 that the vertical
laser line runs centrally through the alignment
aid 14. Then, align the alignment plate with the
alignment aids 12 or 13 with regard to the refer-
ence line.
For cross line or in vertical operation, the verti-
cal laser line on the floor indicates a 45° angle
to the reference line. Align the flooring plates
with regard to this line.
Projecting Plumb Points to the Ceiling
(see figure H)
Draw two lines crossed at a right angle through
the point that you want to project to the ceiling.
Place the alignment plate 11 onto the crossed
lines and align it with the alignment aids 12 and
13 on the cross.
Position the measuring tool via the tripod mount
5 onto the pin 15 of the alignment plate. Posi-
tion it in such a manner on one of the two outer
protrusions on the alignment plate that the ver-
tical laser line runs centrally through the corre-
sponding alignment aid 12 or 13. Select vertical
operation and draw the centre of the line run-
ning across the measuring tool to the ceiling.
Turn the measuring tool on the alignment plate
by 90°. Pay attention not to move the position
of the alignment plate. After levelling in, draw
the cross point of the vertical laser line to the al-
ready drawn line. The cross point of both lines
is the projected plumb point.
1 609 929 K01 | (1.10.07)

Maintenance and Service

Maintenance and Cleaning

Store and transport the measuring tool only in
the supplied protective case.
Keep the measuring tool clean at all times.
Do not immerse the measuring tool into water
or other fluids.
Wipe off debris using a moist and soft cloth. Do
not use any cleaning agents or solvents.
Regularly clean the surfaces at the exit opening
of the laser in particular, and pay attention to
any fluff of fibres.
If the measuring tool should fail despite the care
taken in manufacturing and testing procedures,
repair should be carried out by an authorized af-
ter-sales service centre for Bosch power tools.
In all correspondence and spare parts orders,
please always include the 10-digit article number
given on the type plate of the measuring tool.
In case of repairs, send in the measuring tool
packed in its protective case 16.

Accessories/Spare Parts

Accessories
Laser viewing glasses 18 . . . . . . 2 607 990 031
Measuring plate with foot 19 . . . 2 607 002 195
Spare Parts
Battery lid 10 . . . . . . . . . . . . . . . 1 609 203 U22
Alignment plate 11 . . . . . . . . . . . 1 609 203 U23
Carrying strap 17 . . . . . . . . . . . . 1 609 203 U34
Protective case 16 . . . . . . . . . . . 1 609 203 U24
Adapter for 5/8" tripod . . . . . . . 1 609 203 C10
Bosch Power Tools

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis