Mounting
Application
The flush-mount letterbox housing
is used primarily to accommodate
letterbox module BKM 611-4/4-...
or compartment module
AFM 611-4/4-... . For systems with
function modules, standard housings
GU 611-4/1 are additionally moun-
ted in row. By inrow mounting of
several BGU 611-4/4-... and/or
GU 611-4/1 units, larger scale
systems can be config-ured without
problems. Max. plaster compen-
sation 15 mm.
BGU 611-4/4 mounting without
function strip
1 Where applicable, connect the
BGU 611-4/4-... units to each other
using the enclosed screws, and
mount either flush with the level
of the prepared plaster, or up to
15 mm deeper.
2 In the case of in-row mounted
units, the intermediate wall of the
housing must be broken out at the
corners.
3 Align the fixing plates in the
BGU 611-4/4-... .
4 Mount the combination frame:
Insert the KR 611-... in such a way
that the sealing profile of the com-
bination frame is open at the
bottom.
5 Suspend the supplied long
fastening bracket at the combination
frame and screw firmly to the fixing
plates of the BGU 611-4/4-... .
6 The intermediate webs in
combination frames from size
800 x 800 mm upwards form a
cross. An adjusting screw for align-
ment of the combination frame is
recessed into this cross. Adjust this
screw as required for plane align-
ment of the intermediate webs in
the combination frame, and support
them against the flush-mount
housing.
Inserting the mounting modules
7 Slot BKM 611-4/4-... or
AFM 611-4/4-... into the
BGU 611 4/4-... from the front.
8 There are lateral orientation tabs
positioned at the side of the BKM/
6
AFM 611-4/4-... which must engage
in the guides provided in
the support edge. The BKM/
AFM 611-4/4-... is then positioned in
the surrounding frame aligned flush
with the front of the frame.
9 Using the two torx screws on the
left and right-hand edge, tighten the
BKM/AFM 611-4/4-... with the
plastic claws behind the shoulders of
the combination frame. The torx
screwdriver is provided with the
mounting module.
Mounting the BGU 611-4/4 with
function modules
10 Punch through the screw holes
in the GU 611-4/1 and screw to a
BGU 611-4/4-.... . If required,
connect several BGU 611-4/4-...
units using the provided screws,
insert the connecting cables in the
GU 611-4/1 and mount either flush
with the prepared plaster or up to
15 mm deeper. Max. plaster
compensation 15 mm.
11 For in-row mounted housing
units, break out the prepunched
corners in the intermediate wall
( see Fig. 2 and 10)
12 Align the fixing plates
BGU 611-4/4-... (see Fig. 3).
13 Mount the combination frame.
Insert the KR 611-... so that the
sealing profile of the combination
frame is open at the bottom
(see Fig. 4)
14 Suspend the supplied long fas-
tening brackets at the combination
frame and screw firmly to the fixing
plates of the BGU 611-4/4-... .
(see Fig. 5)
15 The intermediate webs in
combination frames from size
600 x 500 mm upwards form a
cross. An adjusting screw for align-
ment of the combination frame is
recessed into this cross. Adjust this
screw as required for plane align-
ment of the intermediate webs in
the combination frame, and support
them against the flush-mount
housing. (see Fig 6)
16 Remove combination terminal
strip from the module packaging,
centre it turned around 45° to the
left on the retaining plate and latch
into position by rotating it around a
quarter turn in the clockwise
direction so that the terminal
designations can be read vertically
positioned one above the other.
17 Strip the connecting cables, press
onto the housing floor, fix using the
cable clamps and connect the
system to the combination terminal
strip in accordance with the relevant
circuit diagram
18 (no illustration)
Insert the mounting frame. Insert the
MR 611-... in such a way that the
sealing film is positioned at the
upper edge of the mounting frame.
If several MR 611-... units are used,
they must always be inserted from
bottom to top that the sealing film
of the lower mounting frame is
positioned underneath the film of
the upper one in fish scale
formation.
19 Screw the MR 611-... using the
provided quick-release screws into
the flush-mount housing, rotating a
quarter turn to the right (until they
reach their stop position).
Inserting the modules
20 (no illustration)
Connect the plug of the ribbon
cable to the combination terminal
strip.
21 Applying a light pressure,
underpin the module in the module
slot of the MR 611-... opposite the
movable locking bolt. Exerting a
slightly higher degree of pressure,
clip into place on the other side.
22 Slot BKM 611-4/4-...
or AFM 611-4/4-... into the
BGU 611-4/4-... from the front.
(see Fig. 7/8)
23 There are lateral orientation
tabs positioned at the side of the
BKM/AFM 611-4/4-... which must
engage in the guides provided in
the support edge. The BKM/
AFM 611-4/4-... is then positioned
in the surrounding frame aligned
flush with the front of the frame.
(see Fig. 7/8)
24 Using the two torx screws on the
left and right-hand edge, tighten the

Werbung

loading

Diese Anleitung auch für:

Bgu 611-4/4-0