Herunterladen Diese Seite drucken

Perform Diagnostic Tests; Access And Select Diagnostic Tests; Create A Disc With An Index Mark; Diagnostic Test 3 - Calibrate Lift Home - Rimage Producer serie Benutzerhandbuch

Brennroboter

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
Rimage Producer III™ and Producer IIIN™ User Guide

Perform Diagnostic Tests

This section provides the information needed to access, select, and perform Producer III and Producer IIIN diagnostic
tests. To perform any of the diagnostic tests, you must ensure that the Producer III or Producer IIIN is not in an error
state.
Important! Perform only the diagnostic tests provided below. Do not attempt to perform other diagnostic tests
without the assistance of a Rimage trained technician.

Access and Select Diagnostic Tests

1.
Power on the autoloader.
2.
Open the front door of the autoloader.
3.
Press and hold the operator button until [BUTTON DIAGNOSTICS] displays on the operator panel.
4.
Release the operator button. The autoloader is in diagnostic test mode.
5.
Press the operator button the same number of times as the test number and hold the button in on the last
press. The autoloader begins the diagnostic test.
For example: To start diagnostic test 3 (calibrate lift home diagnostic test), press the operator button three
times and hold it on the third press.
Tip: To display each diagnostic test number and name, press the operator button at a rate that is slow
enough so that you can read the test on the operator panel. If you passed the desired diagnostic test,
release the operator button. After the operator panel displays the 01 diagnostic test, select the desired
diagnostic test.
6.
Continue with the desired diagnostic test.

Create a Disc with an Index Mark

Diagnostic test 5 requires a disc with an index mark.
Use a black permanent marker and draw a line on a disc
near the center as shown.
Note: The mark should be at least 1 mm wide and 4
mm long.
Diagnostic Test 3 – Calibrate Lift Home
This diagnostic test calibrates the lift arm to accurately detect the number of discs in the carousel bins.
Tip: This diagnostic test uses the carousel motor, lift motor, carousel sensor, and the lift home sensor.
1.
Remove all discs from the carousel bins.
2.
Place one disc in bin 1.
Caution: Be sure that there is only one disc in bin1 and no discs in any other bin. If you attempt to perform
this test with more than one disc in the unit it will cause miscalibrations which can damage the lift arm and
recorders.
14
Downloaded from
www.Manualslib.com
manuals search engine
1 mm
4 mm
2000538_B

Werbung

loading