3. General data
The accuracy relates to 1 year at a temperature between 18°C – 28° and 75%
humidity (yearly calibrations are offered).
Autoranging and manual measurement range selection
Max. voltage between the connection socket and ground: 400 V
DC/AC
Fusing:
Max. operating height:
Height of display:
Display:
Polarity indicator
Overrange indicator:
Sampling rate:
Low battery status:
Automatic power off
Power supply:
Operating temperature:
Storage temperature:
Dimensions:
Weight:
Test Standard:
Volts DC:
RANGE
200 mV
2 V
20 V
200 V
400 V
Input impedance: 10 MΩ
Max. input voltage 400 V DC
F 200 mA(4 A)/400 V quick-blow fuse
2000 m above MSL
200 mm, LCD
Max. 1999 (3½ )
Automatic
'OL' is displayed
Approx. 0.4 s
Battery symbols is displayed
After approx. 15 min
2 x 1.5 V AAA Micro
0 °C to 40 °C
-10 °C to 50 °C
143 x 72 x 33 mm
400 g incl. batteries
IEC/EN 61010-1
RESOLUTION
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
- 15 -
ACCURACY
± 0.5% of rdg. + 3
digits
± 0.8 % of rdg.
+ 5 digits