6.
Instructions for use
Important:
Check that the pool pump is circulating the water with an adequate water flow.
6.1. Initial startup of the heat pump
1. Checks to be performed before starting the heat pump
• The pool hose connections must be tight,
• The unit must be standing upright, be stable and be on a completely level surface.
• The power supply cable must not be exposed to sharp or hot objects
2. Additional checks must be performed by a qualified technician:
• The function of all safety components must be checked.
• Check that all metal elements are correctly earthed.
• The power connection and fitting of the electric power cable must be checked
Important:
Incorrect installation can cause overheating and will void the warranty.
3. Display Controller
When the heat pump is running, the display shows the water inlet temperature.
LED 1 lights up when compressor is running.
LED 2 lights up if malfunction occurs.
3. Starting and Stopping the heat pump
Turn on the filter pump, check for water leaks and check the water flow of the swimming pool.
Press A to turn on the heat pump. The display shows the water setting temperature for 5 sec-
onds and then the water inlet temperature. Press A to turn off the heat pump.
4. Set the water temperature
Press B or C in order to adjust the water temperature between 10-42 °C.
Press A to save the setting.