Selftest Action; Selftest Ramtest - Hirschmann Msp40 Referenzhandbuch

Hios-2a
Vorschau anzeigen Andere Handbücher für MSP40:
Selftest
71.1 selftest
71.1
selftest
Configure the selftest settings.
71.1.1

selftest action

Configure the action that a selftest component should take.
Mode: Global Config Mode
Privilege Level: Administrator
Format: selftest action <P-1> <P-2>
Paramete
Value
r
task
P-1
resource
software
hardware
log-only
P-2
send-trap
reboot
71.1.2

selftest ramtest

Enable or disable the RAM selftest on cold start of the device. When disabled the device booting time
is reduced.
Mode: Global Config Mode
Privilege Level: Administrator
Format: selftest ramtest
no selftest ramtest
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no selftest ramtest
634
Meaning
Configure the action for task errors.
Configure the action for lack of resources.
Configure the action for broken software integrity.
Configure the action for detected hardware errors.
Write a message to the logging file.
Send a trap to the management station.
Reboot the device.