Herunterladen Inhalt Inhalt Diese Seite drucken

Information - Fault Causes; Technical Data For Control Inputs; Wiring Diagrams - Helios GigaBox GB EC T120 Serie Montage- Und Betriebsvorschrift

Radialventilatoren für fördermitteltemperaturen bis max. 120 c
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation and Operating Instructions
EN
CHAPTER 6
FAULT CAUSES
CHAPTER 7

WIRING DIAGRAMS

Art.-Nr. Type
6372
GBW EC 355 T120
6453
GBW EC 400 T120
6475
GBW EC 450 T120
6452
GBD EC 355 T120
6445
GBD EC 400 T120
6476
GBD EC 450 T120
6477
GBD EC 500 T120
6481
GBD EC 560 T120
6485
GBD EC 630 T120
All manuals and user guides at all-guides.com
GigaBox GB.. EC T120
6.0
Information – Fault causes
Motor is not running:
– lack of power supply
– Motor was deactivated by internal motor protection device
– defective motor
Abnormal noises can be caused by
– incorrect direction of rotation
– worn out ball bearings
– lack of vibration decoupling to other buildings and ducting systems.
Vibrations and oscillation can be caused by:
– unbalanced or dirty impellers
– lack of vibration decoupling to other buildings and ducting systems
Extreme reductions in performance can occur
– in case of incorrect direction of rotation
– if resistance to air stream through ducting and accessories (grilles, shutters, filters etc.) is higher than planned.
– incorrect voltage
– bearing damage
– contamination
7.0

Technical data for control inputs

10 V / 20 mA 0-10 V / 0.167 mA
(Ri = 60 kOhm)
10 V / 20 mA 0-10 V / 0.167 mA
(Ri = 60 kOhm)
10 V / 20 mA 0-10 V / 0.167 mA
(Ri = 60 kOhm)
10 V / 20 mA 0-10 V / 0.167 mA
(Ri = 60 kOhm)
10 V / 20 mA 0-10 V / 0.167 mA
(Ri = 60 kOhm)
10 V / 20 mA 0-10 V / 0.167 mA
(Ri = 60 kOhm)
10 V / 20 mA 0-10 V / 0.167 mA
(Ri = 60 kOhm)
10 V / 20 mA 0-10 V / 0.167 mA
(Ri = 60 kOhm)
10 V / 20 mA 0-10 V / 0.167 mA
(Ri = 60 kOhm)
100
76
100
59
100
76
100
59
100
76
100
59
100
76
100
59
100
76
100
59
100
76
100
59
100
76
100
59
100
76
100
59
100
76
100
59
8
2 changer
59
via EC
motor
(error/motor runs)
24 V AC/DC 1 A
59
via EC
2 changer
(error/motor runs)
motor
24 V AC/DC 1 A
2 changer
59
via EC
(error/motor runs)
motor
24 V AC/DC 1 A
2 changer
59
via EC
motor
(error/motor runs)
24 V AC/DC 1 A
2 changer
59
via EC
motor
(error/motor runs)
24 V AC/DC 1 A
2 changer
59
via EC
motor
(error/motor runs)
24 V AC/DC 1 A
2 changer
59
via EC
motor
(error/motor runs)
24 V AC/DC 1 A
59
via EC
2 changer
(error/motor runs)
motor
24 V AC/DC 1 A
2 changer
59
via EC
motor
(error/motor runs)
24 V AC/DC 1 A
1223,1
1223,1
1223,1
1214,1
1214,1
1214,1
1214,1
1214,1
1214,1

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Gigabox gbw ec 355 t120Gigabox gbw ec 400 t120Gigabox gbw ec 450 t120Gigabox gbd ec 355 t120Gigabox gbd ec 400 t120Gigabox gbd ec 450 t120 ... Alle anzeigen

Inhaltsverzeichnis