Horizontal installation of the pump
with the stand
(Only
ProMax
Pressure
5500/5, 6000/8)
The pump can be horizontally installed
with the stand in a shallow tank or well.
• The pump has to be aligned exactly hor-
izontally.
• Ensure that the water to be pumped
does not contain any sand.
How to proceed:
 E
1. Remove the Allen screws.
– The stand consists of two sections.
2. Push two mounting feet onto each stand
section.
3. Push three rubber pads each into the
grooves of the opening of the stand sec-
tions.
– Fit rubber pads to both stand sec-
tions.
4. Push both stand sections onto the
pump.
– The stand sections should be spaced
as far apart as possible to ensure the
stability of the pump.

OPERATION

The pump control system switches the
pump on and off automatically.
• The pump control system (flow control)
measures the flow and switches the
pump off if the water flow stops.
• The pump switches off when there is in-
sufficient water, protecting it from being
damaged by running dry.
• The integrated non-return valve pre-
vents water from flowing back into the
pump from the pressure hose when it is
switched off. The non-return valve also
prevents damage to the pump resulting
from water hammer.
Starting up the pump
Automatic
W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocu-
tion.
• Only connect the pump to the power
supply when there are no persons in or
reaching into the water.
• Before stepping into or reaching into the
water, switch off all units located in the
water.
• Insert the power plug into the socket.
– The pump is ready for operation.
– The pump switches on automatically
when water is used and the pressure
in the pressure line falls below
3.5 bar.
– The pump switches off automatically
when no more water is used and the
maximum pressure in the pressure
line is reached.
N O T E
If the water is sandy (e.g. in a new foun-
tain) and the unit is operated for a short
time only, sand may accumulate in the
pump, causing the non-return valve or
running unit to jam.
• Allow the pump to run for approx. 1 hour
without interruptions until the sandy wa-
ter has been removed completely.
Taking the pump out of operation
• Disconnect the power plug.