Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Procedure; Turning On The Power; Adjusting The Cable Compensation Of Each Camera; Genlock Adjustments For Each Camera - Panasonic AW-CB400L Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22

Operating procedure

$ Turning on the power

Turn on the power.
First set the power switch on the AC adaptor used for the ROP and the AC power switches on the cameras to ON, and set
the OPERATE switch on the ROP to ON.

$ Adjusting the cable compensation of each camera

For details on providing cable compensation for the cameras, refer to the instruction manual provided with the cable
compensation unit.

$ Genlock adjustments for each camera

If the cameras are to be used in the genlock mode, phase adjustment is required in order to adjust the phases between the
cameras and other units. Genlock adjustment is not needed if genlock is not going to be used.
Horizontal phase adjustment
1 Select the first camera to be adjusted by pressing the CAM CONTROL button.
2 Press the MENU button, and display the camera setting menu on the LCD panel.
3 Turn the CONT dial, and display the G/L SETTING menu.
4 Push the CONT dial straight down, and display H PHASE on the bottom line of the LCD.
5 Observe the waveforms of the genlock signal (black burst signal or video signal (VBS)) and video signal output on an
oscilloscope, and adjust the CONT dial in such a way that the horizontal phase is adjusted as shown in the figure below.
6 Select the next camera by pressing the CAM CONTROL button, and adjust the horizontal phase of the next camera.
Repeat this for all the connected cameras.
External sync (genlock)
signal input (black
burst signal)
Video signal output
Adjust the horizontal phase here.
12 (E)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis