Herunterladen Inhalt Inhalt Diese Seite drucken

Problembehandlung - Suntec Wellness KLIMATRONIC COMFORT 7.0 Eco R290 Bedienungsanleitung

Mobiles lokales klimagerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Please align the hose to avoid the presence of a air trap in the hose.
Cleaning
Cleaning the housing
1. Press the POWER button to turn off the power and unplug the power cord.
2. Please use a neutral detergent with a soft cloth to clean the exterior surfaces and a dry cloth to dry them
off.
3. Please do not use petrol or other chemical cleaning agents to clean the unit.
Cleaing the air filter (every two weeks)
Dust collects on the filter and restricts the air flow. The restricted airflow reduces the efficiency of the system
and can cause damage to the unit if clogged.
The air filter must be cleaned regularly. The air filter is removable for easy cleaning. Do not operate the unit
without the air filter as this may contaminate the evaporator.
1. Please remove the filter fabric from the unit.
2. Use a vacuum cleaner to remove dust from the filter.
3. Please turn the filter over and rinse the air filter under running water. Let the water flow through the
filter in the opposite direction to the air flow. Set the filter aside and allow it to air dry completely before
reinstalling.

Problembehandlung

Problem
The device does
not work.
The device
operates at
reduced power
Water is leaking.
Excessive noise.
Control
Please check the power
connection.
Check that the water level
indicator is lit. The display
shows
.
Check if the room temperature
is too high / too low
Check the air filter for dirt.
Check whether the air outlet is
blocked.
Check whether the door or
window of the room is open.
Check if the desired mode is
selected and that the
temperature is set correctly.
The exhaust hose is
disconnected.
Overflow when moving the
unit.
Check whether the drain hose
is bent or kinked.
Check that the unit is securely
positioned.
Check for loose, vibrating
parts.
Beware!
Do not touch the surface of the evaporator
with your bare hand as this may cause injury
to fingers.
Solution
Please plug the mains cable
firmly into the socket.
Please empty the water tank.
(see section "Error codes")
The operating temperature
range is 5-35℃.
Please clean the air filter if
necessary.
Remove the blockage.
Keep the doors and windows
closed.
Set the mode and temperature
to the correct setpoint according
to the instructions.
Please make sure that the
exhaust hose is not stuck.
Please empty the water tank
before transport.
Please align the hose to avoid
the presence of an obstacle.
Please place the unit on a level
and solid floor.
Secure and tighten the parts.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Klimatronic comfort 9.0 eco r290

Inhaltsverzeichnis