Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Regulations; Maintenance And Periodical Checks; Trouble Shooting - Hamach HR 2400 Gebrauchsanleitung

Spraygun washer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
CLEANING THE FILTER UNIT
The following operations have to be checked according to local law and regulations!
When the contaminated water has drained into the filter unit, turn the faucet of the washer into the
horizontal position. The filter unit is placed onto a small trolley with 4 wheels (no castor wheels) and
can be moved to a canalisation by placing it onto a cart. By opening the faucet at the backside of the
filter unit the liquid will drain directly into the canalisation. When all the liquid is drained, close the ball
valve. Deposit the fine filter with contaminated material in a suitable waste bin and have it discarded
according to local regulations. Place a new filter. Place the filter unit back under the washer, to make
it ready for use again.

SAFETY REGULATIONS

The following parts may never be manipulated or turned off and must always be kept in perfect
working condition:
Earth wire

MAINTENANCE AND PERIODICAL CHECKS

Only those maintenance operations named in this paragraph (general maintenance) are to be carried
out by the user. All other maintenance must be carried out by a qualified maintenance
person.
The following operations can be carried out by the user:
The cleaning of the working plain and the HR 2400 inside parts;
The cleaning of the basin inside grill;
The cleaning of all the nozzles;
The cleaning of the HR 2400 outside with a neutral product and a soft cloth;
The changing of the filter on the backside of the inside of the machine (Paint Stop filter).

TROUBLE SHOOTING

Problem
After the machine has been
connected to compressed air, it
does not deliver liquid to the
distributor.
FOR ALTERATIONS IN THE CIRCUITS, CONTACT HID SERVICES IN ZWOLLE, THE
NETHERLANDS.
Possible cause
The
pressure
is
not
enough.
The distributor feed valve is not
opened.
The basin is full.
Solution
high
Check the air feed system.
Open the distributor feed valve.
Use the appropriate coagulation
powder to treat the water.
33