Herunterladen Inhalt Inhalt Diese Seite drucken

Making Connections To Use The Word Clock Of A Connected Unit As The Clock Master - Tascam 8p Dyna SERIE Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 51
Making connections to use the word
clock of a connected unit as the clock
master
These connection settings also apply to other audio interfaces
with WORD OUT connectors.
Connection example when using the word
clock of a connected device as the clock
master at a 44.1/48kHz sampling frequency
TASCAM SERIES 208i
TASCAM SERIES 8p Dyna
Cable connections
o Use one optical cable to connect either the A or B
OPTICAL IN (S/MUX) connector of a TASCAM SERIES 208i
to the A or B OPTICAL OUT (S/MUX) connector of this unit.
o Use a BNC cable to connect the WORD OUT connector of
a TASCAM SERIES 208i to the WORD IN connector of this
unit.
Setting the switch
o Set the 75Ω ON/OFF/THRU/WORD OUT switch on this unit
to ON.
Setting the sample clock source
o To set the clock source of the TASCAM SERIES 208i, set the
Settings Panel INFORMATION screen Sample Clock Source
item to "INTERNAL".
o Use the sample clock switch to set the clock source of this
unit to EXT. (see "Switching the sample clock" on page
12)
Connection example when using the
word clock of a connected device as the
clock master at 88.2/96kHz (S/MUX2)
or 176.4/192kHz (S/MUX4) sampling
frequencies
TASCAM SERIES 208i
TASCAM SERIES 8p Dyna
Cable connections
o Use 2 optical cables to connect the OPTICAL IN (S/MUX)
connectors of a TASCAM SERIES 208i to the OPTICAL OUT
(S/MUX) connectors of this unit.
o Use a BNC cable to connect the WORD OUT connector of
a TASCAM SERIES 208i to the WORD IN connector of this
unit.
Setting the switch
o Set the 75Ω ON/OFF/THRU/WORD OUT switch on this unit
to ON.
Setting the sample clock source
o To set the clock source of the TASCAM SERIES 208i, set the
Settings Panel INFORMATION screen Sample Clock Source
item to "INTERNAL".
o Use the sample clock switch to set the clock source of this
unit- to EXT. (see "Switching the sample clock" on page
12)