Herunterladen Inhalt Inhalt Diese Seite drucken

Battery Charging Parameters - Renogy ROVER PG Serie Installation Und Handbuch

Solarregler mit mppt-technologie
Vorschau ausblenden Andere Handbücher für ROVER PG Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 32
This equipment has been tested and found to comply with the limits for a class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.

Battery Charging Parameters

Battery
Over-voltage
Warning
Equalization
Voltage
Boost Voltage
Float Voltage
Boost Return
Voltage
Under Voltage
Warning
Under Voltage
Recover
Low Voltage
Disconnect
Low Voltage
Reconnect
Equalization
Duration
Boost Duration
*Battery charging parameters in USER mode can be programmed using the Renogy BT App.
**Default charging parameters in LI mode are programmed for 12.8V LFP battery. Before
using Rover PG to charge other types of lithium battery, set the parameters according to the
suggestions from battery manufacturer.
***Parameters are multiplied by 2 for 24V systems.
EN
GEL
SEALED
16 V
16 V
-----
14.6 V
14.2 V
14.4 V
13.8 V
13.8 V
13.2 V
13.2 V
12V
12V
12.2 V
12.2 V
11.0V
11.0V
12.6 V
12.6 V
2 hours
-----
2 hours
2 hours
FLOODED
LI (LFP)
16 V
16 V
-----
14.8V
14.6 V
14.4 V
13.8 V
-----
13.2 V
13.2 V
12V
12V
12.2 V
12.2 V
11.0V
11.0V
12.6 V
12.6 V
2 hours
-----
-----
2 hours
USER
9-17 V
9-17 V
9-17 V
9-17 V
9-17 V
9-17 V
9-17 V
9-17 V
9-17 V
0-10 Hrs.
1-10 Hrs.