WIRING SPECIFICATIONS
The system supports two electric strike release configurations: with the open
command output by (i) an entrance panel or (ii) a system display (the display open
command output wire must have the shield connected to earth). If the open
command is output by an entrance panel, follow this wiring specification:
• If the entrance panel is < 30 m away from the video entry phone display, use
YTDYw 4x0.5 mm2 wiring.
Tekst
MONITOR
CZERWONY
NIEBIESKI
ŻÓŁTY
BIAŁY
ZIELONY
BRĄZOWY
CZARNY
ELEKTROZACZEP
PANEL ZEWNĘTRZNY
• If the entrance panel is > 30 m away from the video entry phone display, use
YTDYw 4x0.5 mm2 wiring.
If the open command is output by a display, follow this wiring specification:
• If the entrance panel is < 30 m away from the video entry phone display, use
YTDYw 6x0.5 mm2 wiring.
• If the entrance panel is < 30 m away from the video entry phone display, use
YTDYw 6x0.8 mm2 wiring.
Translation
DISPLAY
RED
BLUE
YELLOW
WHITE
GREEN
BROWN
BLACK
ELECTRIC STRIKE
ENTRANCE PANEL