Herunterladen Inhalt Inhalt Diese Seite drucken

Conduct In Case Of Faults; Error Codes Of The Operating/Service Led Display; Error Codes Of The Supply Voltage Led - Weidmuller EPG CUT 40 Originalbetriebsanleitung

Akku-hydraulisches schneidewerkzeug
Vorschau ausblenden Andere Handbücher für EPG CUT 40:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5.

Conduct in case of faults

5.1

Error codes of the operating/service LED display

In case of any fault, the EPG CUT 40 Power Tool will be switched off and remain disabled. The
service LED will glow red or orange. You can proceed with your work only after the battery has
been exchanged or removed for short time and is then re-inserted (RESET). If the malfunction
persists even after such a "reset", please contact Weidmüller's after-sales service.
LED-Display
after application (cycle)
steady green
flashing red/green
flashing red
steady red
steady orange
after power on (battery insertion)
steady green
steady orange
steady red
The fault massages can be read out using the analysis software. Please return the faulty working
diagrams to our service center.
5.2

Error codes of the supply voltage LED

Failure
after application (cycle)
flashing red
steady red
after power on (battery insertion)
steady green
steady red
2516420000 /00/04.2017
Cause / remedy
Working value OK
Working value OK but service interval exceeded / Service
Working value is at the limit / contact the service center
Working value is outside range /
return device to customer service
Temperature is outside the tolerance range /
cool or warm the device
Power tool is ready for operation
Temperature is outside the tolerance range /
cool or warm the device
Battery empty / change the battery.
Cause / trouble shooting
Battery charge is below 10% / Change the battery.
Battery empty / change the battery.
Power tool is ready for operation
Battery empty / change the battery.