ELECTRICAL CONNECTION
Before connecting the appliance make sure that the voltage
and frequency rated on the data plate conform to those of the
mains supply.
• The appliance works off a single phase 230 V 50 Hz power
supply (see wiring diagram).
• The geared motor must be earthed, to this end use the binding
post marked
which can be found on the wiring box.
• Do not use cables with aluminium conductors; do not solder the
ends of cables which are to be inserted into the binding posts;
use cables which are marked T min 85°C and are resistant to
atmospheric agents.
• The power cable must have enough slack to make sure it is not
pulled tight during normal operation.
• The power cable must not be wound around any of the appli-
ances components and must not be cemented into the wall.
An double pole circuit breaker with a minimum of 3 mm
between the contacts must be installed between the electronic
programmer and the mains supply.
• Connect the supplied capacitor between the live wires 2 and
3 of the geared motor (fig. 19-21 pag. 9-11).
Power cable rubber sealing cap
1) Fit the sealing cap on to the power
cable and slide it down enough to
allow you to connect the cable to the
terminal board.
2) Fasten down the cable using the cable
clamp.
3) Close the cover and slide the sealing
cap up over the cable entry opening.
This action is extremely important and will
guarantee a protection grade of IP44.
IMPORTANT! The geared motor is not fitted with a torque
limiter. Only use an electronic programmer which has a torque
limiter with maximum force at the head of the gate equal to
150 N (local standards and regulations in force).
SETTING THE MOTOR TORQUE (see electronic programmer)
When carrying out the installation you are advised to use a Cardin
electronic programmer fitted with a torque limiter.
The Cardin programmers optimise the correct working order of the
"machine" (motorised gates/doors) and guarantee full power maxi-
mum thrust at the start of the opening/closing manoeuvre).
The programmer also guarantees that the effective torque fed to
the system will be that selected by the operator in the electronic
programmer. The choice of settings depends on the weight and
size of the gate leaf/door and the different environmental conditions
on-site.
You are reminded that the standards and regulations in force
unequivocally require that the torque be set to a level suitable
for the system.
Correctly choosing the torque will guarantee maximum security
and long life for the mechanical components.
(fig. 19-21 page 9-11)
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
SCALA: 1:2
Description :
Prodotti Technocity
Drawing number :
DI0131
Collegamento gommino protezione
Product Code :
BL202
Date :
Draft :
P.J.Heath
01-07-99
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
SETTING THE MECHANICAL TRAVEL LIMIT (fig. 3 pag. 3)
The model 200/BL203C - 200/BL203CE is fitted with adjust-
able mechanical travel limits "7" and "10". Loosen the fastening
screws and move the rings "7" and "10" to the desired opening
and closing positions then tighten them carefully.
MANUAL RELEASE MECHANISM
Releasing the gate should only be carried out when the motor
has stopped because of blackouts.
To release the gate use the plastic key supplied with the appliance.
It should be stored in an easily accessible place, at home or on
the appliance itself using the key slot (pos. 5 fig. 12).
To release the gears
- open the lock mechanism cover by pressing on the sides (fig
12a-12b);
- insert the release key and turn it through about 30 degree
(fig. 12c). The gears will be released and the lock cylinder will
rise;
- if you wish leave the gears released, just close the lock cylinder
cover (fig. 12e).
To lock the gears
- remove the key (fig. 12d), close the cover and press down with
the palm of your hand until the gears are locked;
- keep the key in a safe place.
Note: To make the operation easier the gate can be moved slightly
if required.
Don't force the locking mechanism, if you encounter
resistance move the gate slightly to allow the cogs to slot
together more easily within the geared motor.
USER INSTRUCTIONS
During the opening/closing manoeuvre check for correct operation
and activate the emergency stop button in case of danger.
During blackouts the gate can be released and manually manoeu-
vred using the supplied release key (see manual release).
Periodically check the moving parts for wear and tear and grease
if required, paying particular attention to the never ending screw
pos. 11 fig. 3 (200/BL203C - 200/BL203CE), using lubricants
which maintain their friction levels unaltered throughout time and
are suitable for temperatures of -20 to +70°C.
In case of failure or operational anomalies switch off the power at
the mains do not attempt to repair the appliance yourself.
Periodically check the correct operation of all safety devices
(photoelectric cells etc.).
Eventual repair work must be carried out by specialised personnel
using original spare parts.
The appliance is not suitable for continuous operation and must
be adjusted according to the model (see technical data on page
28).