Herunterladen Diese Seite drucken

Electrical Connection - Grundfos E-Box 500 Installations- Und Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für E-Box 500:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14

3.2 Electrical connection

The electrical connection must only be carried out by
an authorised electrician in accordance with local
regulations.
Warning
Before beginning the electrical connection,
make sure that the power supply of the
DDA dosing pump has been switched off,
and that it cannot be accidentally switched
on.
Warning
To ensure enclosure class IP65 / NEMA
4X, all unused connections have to be
fitted with a blind plug!
Supply voltage of the E-Box: 30 VDC from
DDA pump. See fig. 1, pos. 4.
Caution
Connect E-box to power supply only via
the SMART digital S DDA pump using the
pre-assembled plug!
To ensure a stable and reliable
communication, the cable screen for
GENIbus connection must always be
connected to the earth clamp. This is
Caution
pre-assembled by Grundfos.
See fig. 1, pos. 4.
Do not make any changes!
3.2.1 Connection of Ethernet
The CIM 500 is designed for flexible network
installation. The built-in two-port switch makes it
possible to daisy chain from product to product
without the need of additional Ethernet switches. The
last product in the chain is only connected to one of
the Ethernet ports. Each Ethernet port has its own
MAC address.
Ethernet
switch
CIM
500
CIM
500
Fig. 3
Example of industrial Ethernet network
1. Remove cover from E-Box.
6
2. Connect Ethernet cables with RJ45 plugs to
3. Connect cable screens to earth via the earth
4. If necessary, connect earth conductor to
CIM
CIM
5. Fit housing cover and tighten screws.
500
500
For further information (e.g. connection to web
server) see installation and operating instructions of
the CIM 500 module.
Fig. 4
Connection of Ethernet
Pos.
Description
1
Ethernet connection 1
2
Ethernet connection 2
3
Optional functional earth connection*
Rotary switch for selection of industrial
6
Ethernet protocol.
7
Earth clamps for cable screens
8
Functional earth terminal
9
Earth clamp
connections (1), (2).
– Depending on the local network installation,
one or two cables can be connected.
clamps (7).
functional earth terminal (8) at earth connection
(3) and tighten clamp (9).
– Make sure that the gasket is positioned
correctly.
The module comes with fixed IP address:
192.168.1.100
Note
The IP address settings can be changed
with the built-in web server.

Werbung

loading