Herunterladen Inhalt Inhalt Diese Seite drucken

Diagnostics In The Input Data Field; Commissioning The Vs With Profinet - Aventics PROFINET VS serie Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Calling up the diagnosis
AVENTICS | PROFINET | R412023897–BDL–001–AA
7.3.2

Diagnostics in the input data field

O
Click the menu item View, Diagnosis.
The diagnostic message is stored in input byte 0.
An explanation of the bits is provided in Table 12.
Table 12:
Meaning of the bits in input 1
Bit
Value
0
0
1
1
0
1
2
0
1
3
0
1
4
1
5
1
6
1
7
1
7.4

Commissioning the VS with PROFINET

Before commissioning the system, the following steps must
have been carried out and completed:
W
You have assembled the valve system and the bus coupler
(see "Assembling the CL03/CL03-XL with PROFINET" on
page 59).
W
You have connected the bus coupler (see "Connecting the
module electrically" on page 61).
W
You have made the switch settings and configured the system
(see "Making settings" on page 65).
W
You have configured the bus master so that it controls the
valves correctly.
Commissioning and Operation
Condition
-
Diagnostic message U
Q1
If bit 0 is set: U
missing
Q1
12.5 V < U
< 21.6 V/20.4 V
Q1
-
Diagnostic message U
Q2
If bit 2 is set: U
missing
Q2
12.5 V < U
< 21.6 V/20.4 V
Q2
UL < 18 V
Short circuit valve driver
Supply for valve blocks 1 and 2 missing
Supply for valve blocks 3 and 4 missing
75

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Profinet cl03Profinet cl03-xl

Inhaltsverzeichnis