Herunterladen Inhalt Inhalt Diese Seite drucken

IKEA FRAMTID HGA2K Bedienungsanleitung Seite 10

Vorschau ausblenden Andere Handbücher für FRAMTID HGA2K:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH
The connection cable has to be placed in order
that, in each part, it cannot reach a 90 °C tem-
perature. The blue neutral cable must be con-
nected to the terminal block marked with "N".
The brown (or black) phase cable (fitted in the
terminal block contact marked with "L") must
always be connected to the live phase.
Replacement of the connection cable.
If the connection cable must be replaced, only
a type H05V2V2-F T90 cable must be used.
The cable section must be suitable to the volt-
age and the working temperature. The yel-
low/green earth wire must be approximately
2 cm. longer than the brown (or black) phase
wire.
To open the terminal block and reach
the terminals, proceed as follows:
1. insert the point of a screwdriver into one of
the two visible protruding part of the ter-
minal block
2. exert a light pressure and lift
The hob is supplied with a three pole terminal
block designed for a 230 V connection. The
yellow/green earth wire must always be con-
nected to the terminal marked with the symbol
.
Upon completion, secure the connection cable
with the cable clamp and close the terminal
block.
Gas setting conversion
This model is designed for use with natu-
ral gas but can be converted for use with
butane or propane gas providing the correct
injectors. The injectors not supplied with the
appliance have to be ordered from After Sales
Service (refer to the Service chapter).
For data concerning injector replacement, see
chapter "Technical data"
Warning! Conversion or replacement
can only be performed by a registered
installer.
To replace injectors:
1. Remove pan support.
2. Remove burner cap and crown.
3. With a socket spanner 7 unscrew and re-
move the injectors, replace them with the
ones required for the type of gas in use.
4. Reassemble the parts, following the same
procedure backwards.
Important! Replace the rating label (placed
near gas supply pipe) with relevant one for the
new type of gas supply before sealing the
appliance. If the appliance is already sealed
please stick it directly on the user manual
booklet after Technical data chapter close to
the rating plate drawing.
You can find this label in package sup-
plied with appliance
10