6. Additional Information
Use the "SFC" command to retrieve these values. See Chapter 5.2 Commands for Selecting
Operating Parameters, page 18.
Measured values
Battery voltage
Output current
Operating time
Operating state
6.3

Explanation of Measured Values

Example
Explanation
12.1 V
Voltage measured at the battery
0.0 A
Charging current measured at the fuel cell
5.8 h
Hours the EFOY Pro fuel cell has been in operation
Operating status of the EFOY Pro fuel cell
Auto on
The fuel cell is working in automatic mode and is
on.
Auto off
The fuel cell is working in automatic mode and is
off.
error
error: There is an error or malfunction. Please
follow the instructions in the EFOY Fuel Cell user
manual.
remote on
The fuel cell is switched on via the remote contact
remote off
The fuel cell is switched off via the remote contact.
Used for Hybrid operation.
If several products are combined via a cluster
Slave on
controller, the following status is indicated for the
non-leading units.
Battery
when the battery protection is acitvated.
protection
Freeze
the fuel cell is being used in the freeze protection
protection
mode.