7.1 Synchronisation of an LLX1 system

Display
43
44
GB
45
46
47
Action
Confirm the selection
ESC
Return to previous window
Select an icon and enable the
available options
Select an icon and enable the
available options
No action
ESC
No action
No action
No action
Confirm the selection
General reset with no addition
ESC
of sensor
Select an icon and enable the
available options
Select an icon and enable the
available options
Confirm the selection
General reset with no addition
ESC
of sensor
Select an icon and enable the
available options
Select an icon and enable the
available options
No action
ESC
No action
Select an icon and enable the
available options
Select an icon and enable the
available options
20
Comments
Go to the parameter setting menu
and select option +
Confirm with
Scan environment:
The display unit scans all the
channels except its own and
identifies all the sensors present
within a radius of 40 m.
Identification of sensor to be
synchronised:
If several sensors (on same channel
as display unit) are present, only the
sensor with the smallest address will
be identified.
XXXXXXXX = Serial No.
2t = capacity
MM YY = calibration date
Before Synchronisation:
Check that the serial No. of the LLX1
identified corresponds to your unit.
Confirm with
If not, switch off the outside unit and
repeat the synchronisation
procedure.
Synchronisation:
After you have confirmed your
selection, the messages "addition in
progress" followed by "completed"
are displayed.
Following this the unit re-boots.
The sensor channel has been
automatically changed.