Page 10
Adjust the Lens
Open the Live View page in the web interface and
make the following adjustments to the camera:
1. Loosen the locking screw and tilt adjustment
screws.
2. Turn the lens (with the lens holder) to the
desired position. Make sure the horizon lines
on either side of the lens are aligned
horizontally and the single slit between the
horizon lines is pointing down.
3. Once satisfied, gently tighten the locking
screw and tilt adjustment screws to secure the
camera's position.
4. Open the Focus Adjustment page in the Web interface under Basic Configuration > Focus &
Zoom, and follow the on-screen instructions. Use the image window to adjust the focus and
zoom.
Note:
Due to the dome's refraction, the image may appear slightly out of focus once the dome has been
placed. To correct this go to the focus page in the Web interface under Basic Configuration>Focus
& Zoom, and adjust the focus again.
Complete the installation
1. If the cables are routed along the wall, remove the side lid from the camera's dome cover.
2. Rotate the black protective shield inside the dome casing to match the camera's position.
3. Clean the dome with a dry soft cloth to remove dust and finger prints and use a blower to
remove dust from the lens.
4. Mount the dome casing using the supplied tamper-proof screws and screw driver. Now that the
dome is in place, check that the camera is properly focused.
The installation is now complete.
AXIS P3343/P3343-V/P3344/P3344-V Installation Guide