Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Notes; Installation Instructions; Symbol Description - HANSGROHE 13620180 Montageanleitung

Vorschau ausblenden Andere Handbücher für 13620180:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The fittings must be mounted in an insulated manner
and with sound insulation.
• The plumbing codes applicable in the respective
countries must be observed.
Assembly
Mount the body in such a way, that the outlet faces to
the top and that the marking on the protective cover is
flush with the face of the tiling.
Depth of fitting: 55 mm to 83 mm.
Note: When installation is complete ensure
that the mixer is turned off!
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Connections G 1/2:
The product is exclusively designed for drinking water!
4
English
Symbol description
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
cold right - hot left
Adjustment (see page 33)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Dimensions (see page 31)
Flow diagram (see page 31)
Rate of flow by 0,3 MPa:
Spare parts (see page 32)
Special accessories
extension set 28 mm (32698000) order as
an extra.
Final assembly (see page 34)
Test certificate (see page 40)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis