Log On to the Vision System
1. Open the In-Sight Explorer software.
2. From the Get Connected Application Step, select your In-Sight vision
system from the Select an In-Sight Sensor or Emulator group box and press
the Connect button.
Vision System Specifications
Specifications
Power Consumption
Power Output
1
Case Temperature
Storage Temperature
Humidity
Protection
Shock (Shipping and Storage)
Vibration (Shipping and Storage)
1
Case temperature can be verified using the EV GetSystemConfig("Internal.Temperature") Extended Native Mode
command. When issued, it returns the vision system's internal temperature in degrees Celsius, which will be about
3 to 5 degrees above the vision system case temperature. Refer to the In-Sight
information. Additional cooling measures are required if the case temperature cannot be kept below 50°C. Examples
of such measures include: extra heat sinking and/or air movement.
7600
7800
24VDC ±10%, 1.5A maximum
24VDC @ 750mA maximum to external light.
0°C to 50°C (32°F to 122°F).
-20°C to 80°C (-4°F to 176°F)
< 80% non-condensing
IP67 with cables and appropriate lens cover attached.
IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z)
2
axis) 80 Gs (800m/s
at 11ms, half-sinusoidal) with cables or cable
plugs and appropriate lens cover attached.
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @
10 Gs (10 to 500 Hz at 100m/s
appropriate lens cover attached.
12
7801
2
/ 15mm) with cables or cable plugs and
®