Storage, Issue & Inspection
Storage
Storage in a central protected location allows assurance of inspection on issue and return.
The device should be stored in a clean dry place where it can be protected from damage by chemical attack and sharp
objects . It should be stored with its instructions and record card at all times.
Return the device back to it's original box or other suitable container for storage & transportation.
After use return to the store, Never leave the device lying around site.
Issue
This and associated equipment must be visually inspected by a competent person when initially delivered to site, there after the
product must be inspected before and after use. A record card is printed in section 5.0 of this manual and should be updated
after each routine inspection. Follow the points laid down in the section headed "Inspection" without deviation.
The supervisor must ensure that the equipment is being used correctly by a trained and/or otherwise competent person who is
aware of its safe use and inspection. Additionally the supervisor must ensure that there are suitable and accessible anchorages
in the working environment to allow safe anchorage of the device.
Inspection
Inspect the device, life line, hook and anchorage for signs of wear, deformation, damage or corrosion.
Webbing (Dyneema) - Ensure that the webbing is free from cuts, abrasion & wear marks.
Ensure hook swivels and twist gate operate and close correctly.
Ensure hook load indicator is not deployed.
Pull line sharply to engage brakes and ensure device locks before each and every use.
Pull out line to ensure that it pays out and recoils smoothly.
All housing screws must be secure.
Check the user instructions are clear & legible.
If the webbing becomes wet in use, ensure webbing is extended & left to dry naturally.
To clean the housing, webbing a mild detergent can be used with warm or cold water. The webbing must be extended from
the device & left to dry naturally.
Ensure that device certification is current before use, the device must have been serviced and inspected within the
last 12 months and 6 months if used in corrosive or off-shore environments.
If for any reason the inspection of this device shows signs for concern or doubt then the device must be quarantined and
removed from service immediately. Advice should be sought from the supervisor and if still concerned the device must be
sent to the supplier, an approved service agent or the manufacturer for service and re-calibration.
The device has an expected useable lifetime of up to five years subject to inspection, providing it has been serviced &
maintained to Crestos recommendations.
This device must only be serviced by a trained and competent individual,
Never attempt to service this unit or tamper with its function in any way.