Make sure that the LM.125 / .250 is well and properly grounded according to the guidelines.
Disconnect power before connecting the cables and only apply power after all the cables have been
connected correctly.
Always observe the regulations of the electricity company.
Mount the cables so they cannot be damaged, and can easily be replaced in the event of a malfunction.
The voltage and frequency data on the actuator identification plate must correspond to the power
supply.
Separate high and low voltage wires by mounting them in separate cable channels.
Limit the length of signal cables as much as possible. Avoid crossing low/high voltage cables.
For electrical connection of the LM.125 / .250 refer to the following diagrams in the appendixes.
Connection LM.125 / .250 single phase
Connection LM.125 / .250 three phase in star connection
Connection LM.125 / .250 three phase in delta connection
The position feedback is done by means of a CPS (contactless position sensor).
A CPS is, in contrast to the potentiometer, not manually adjustable.
A limit switch set with CPS has a grey sprocket wheel in the middle.
1.
Check whether the LM.125 / .250 has been connected correctly.
2.
Check whether the LM.125 / .250 works optimally.