3.6 Time delay

In order to protect the electrical circuit, the heat pump has a built in 3-minute start-up
delay. This is also in order to avoid excessive wear and tear of switches. The unit starts
automatically when the time delay has expired. Even a short power outage will trigger the
start-up delay and prevent the device restarting immediately. Further power cuts within the
same 3-minute period will not further extend the start-up delay.
NOTE
The heat pump must be earthed. We recommend the purchase of a Schuko plug.
4.

Instructions for use

4.1. Control buttons on the LED panel
When the heat pump is in operation the LED display shows the water inlet temperature.
LED 1 is lit when the compressor is in operation.
LED 2 is lit when there is a fault.
4.2. Turn the heat pump on/off
Press
to turn on the heat pump. The LED display shows the set water temperature for
5 seconds, and then changes to show the current water inlet temperature.
Press
again to switch off the heat pump.
4.3. Setting the water outlet temperature
Press
or
Press
to save the settings and exit the menu.
MV-1295-1296-1297-06-2019 . swim-fun.com © All rights reserved Swim & Fun Scandinavia ApS
to adjust the water outlet temperature (interval: 10-42 °C).