Applications
Fitting for use with concealed fitting body 36 068 in conjunction
with function unit 36 067.

Technical Data

• Flow rate at 3 bar flow pressure:
Spout
Shower
• Automatic safety shut-off (factory setting):
• Safety stop (factory setting):
• Type of protection:
• Type of protection:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Note:
GROHE fittings with showers are equipped with non-return
valves.

Approval and conformity

This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Refer to the dimensional drawing on fold-out page I.
I. Fitting, see fold-out page II, Figs. [1] to [3].
1. Insert adapter tube (A) with mounting set (B) from below and
attach escutcheon (C), see Fig. [1].
1. Observe the correct installation position!
2. Tighten adapter tube (A) using fitting key (D), see Fig. [2].
3. Fasten connection nipple (E) with clamp (E1) and connect
hose (F).
4. Screw in adapter (G) and insert decorative trim (H) in
escutcheon (C), see Fig. [3].
5. Fit spout (J) and fasten with set screw (K).
6. Insert plug (K1).
II. Hand shower, see fold-out page II, Figs. [4] and [5].
1. Insert hand shower holder (L), screw on mounting set (M)
and fasten using fitting tool (L1), see Fig. [4].
2. Connect shower hose (N) to hose (O), see Fig. [5].
3. Fit escutcheon (P), see detail. Screw in bracket (Q) securely
by hand.
4. Feed through shower hose (M) from below and screw on
taper nut (R1).
5. Install hand shower (R).
3
approx. 20 l/min
approx. 12 l/min
30 min
39 °C
IP 57
- Fitting
IP 54
- Operating panel
IP 57
B
2
2500 V
100 °C
III. Wall adapter, see fold-out page II, Figs. [6] to [9].
1. Cut fitting template (S) to length, see Fig. [6].
2. Guide plug-in connector (T) through wall adapter (U), see
Fig. [7].
3. Insert wall adapter (U) and turn through 45°, see Fig. [8].
The fitting depth of wall adapter (U) can be adapted to the
wall thickness by turning the internal screws (U1).
4. Align wall adapter (U) and tighten internal screws (U1), see
Fig. [9].
IV. Operating panel, see fold-out page II, Figs. [10] and [11].
1. Attach connector (T) to connector (V1) of operating
panel (V) and push back into the concealed fitting body, see
Fig. [10].
2. Insert operating panel (V) in wall adapter (U).
3. Fasten operating panel (V) using set screws (W), see
Fig. [11].
Open cold and hot-water supply and check connections
for water-tightness.

Operation

Using the operating panel
Start/Stop button
Operational readiness of fitting. Water flow
commences following actuation of a programme
button. Repeated actuation stops water flow.
The connected outlets can be operated
simultaneously.
Pause button
Interrupts the flow of water (temperature arrow on
operating panel orange). The flow is resumed by
pressing the button again.
The fitting switches off automatically after a preset
time in pause mode (factory setting 60 s).
Temperature
Increases (red arrow, left) or decreases (blue arrow,
right) the water temperature.
The display flashes until the preset temperature is
reached.
Volume
Increases
or decreases the flow rate in a total of
eight stages.
Temperature safety button
Overriding the safety stop (factory setting: 39 °C).
The actual value is synchronised with the display at 38 °C. See
Calibrate in the section Setting mode.
Programme buttons
Drench shower head
Head shower
Side shower