en - Installation and connection
If the machine fan is not powerful enough to remove the moist air, a suitably powerful addi-
tional fan must installed in the shaft or the roof outlet on-site.
Make sure that a sufficient air quantity is fed to the room in which the appliance is installed
(e.g. non-lockable ventilation openings).
If the exhaust ducting is leading upwards, a condensate drain hole with a diameter of 3–
5 mm must be provided at the lowest point.
The on-site ducting system and the exit point to the outside must be checked on a regular
basis for a build-up of lint. Clean them if required.
The end of ducting leading outside must be protected against the elements, e.g. with a
downward-facing 90° bend, without any grills or louvers fitted. The ironer must not exhaust
into a plenum box.
82