O
PERATION LOCK
This function locks operation mode only. Other functions, such as OFF/
ON, temperature setting, or airfl ow direction adjustment, are available.
1
Hold down
and
onds while the unit is not operating to enable OPERA-
TION LOCK.
The icon for the locked operation mode blinks.
2
Hold down
and
seconds again while the unit is not operating to disable

OPERATION LOCK.

The icon for the locked operation mode blinks when
and
are held down to enable or disable
OPERATION LOCK or
tion while OPERATION LOCK is enabled.
AIR PURIFYING operation is not available when OP-
ERATION LOCK is enabled in a mode other than FAN
mode.
simultaneously for 2 sec-
simultaneously for 2
is pressed during opera-
E
MERGENCY OPERATION
When the remote controller cannot be used...
Emergency operation can be activated by pressing the emergency operation
switch (E.O.SW) on the indoor unit.
Each time the E.O.SW is pressed, the operation changes in
the following order:
Operation indicator lamp
Emergency COOL
Emergency HEAT
Stop
Note:
• The fi rst 30 minutes of operation is test run. Temperature control does not
work, and fan speed is set to High.
• In the emergency heating operation, the fan speed gradually rises to blow out
warm air.
• In the emergency cooling operation, the horizontal vanes' position will be
reset in about a minute, then the operation will start.
A
UTO RESTART FUNCTION
If a power failure occurs or the main power is turned off during operation, "Auto
restart function" automatically starts operation in the same mode as the one set
with the remote controller just before the shutoff of the main power. When timer is
set, timer setting is cancelled and the unit starts operation when power is resumed.
If you do not want to use this function, please consult the service repre-
sentative because the setting of the unit needs to be changed.
Set temperature : 24°C
Fan speed : Medium
Horizontal vane : Auto
En-14