connected to the terminal block label with "N". The
brown (or black) phase cable (fitted in the terminal
block contact marked with "L") must always be con-
nected to the live phase.
Replacement of the connection cable
To replace the connection cable use only H05V2V2-F T90
type. Make sure that the cable section is applicable to the
Assembly
min. 650 mm
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy to remove
and let an easy access in case a technical assistance in-
tervention is necessary.
a
60 mm
b
490 mm
270 mm
A - seal to remove
B - supplied brackets
30 mm
min 20 mm
(max 150 mm)
voltage and the working temperature. The yellow/green
earth wire must be approximately 2 cm. longer than the
brown (or black) phase wire.
a) Removable panel
b) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the indication and
must be equipped with brackets to let a continuous supply
of air for safety reasons. The electrical connection of the
hob and the oven must be installed separately. It also lets
the oven to be easily taken off the unit.
50 cm
360 cm
MANUFACTURER:
ELECTROLUX ITALIA S.p.A.
C.so Lino Zanussi, 30
33080 PORCIA (PN) - ITALIA
A
B
2
120 cm
180 cm 2
2