Assembly
1. Flush through the supply pipes.
2. Mount the ball S - unions.
Hot water connection left hand, cold water
connection on the right hand side.
3. Screw the escutcheons down the wall.
4. Fasten the mixer using union nuts, align and
tighten it.
The S - unions enable inaccuracies in the wall.
Large differences in pressure between the hot and cold
water supply should be balanced.
Adjustment
Correction is necessary if the temperature measured
at the take off point differs from the temperature set
on the scale. To adjust please see page 6.

Operation

The mixer is operated by turning the handle on the
left hand side.
The temperature is selected by turning the
graduated handle on the right side.
The flow of the bath mixer can be changed from tub
to shower function by simply pulling the diverter
knob located at the top of the outlet. When the
water is shut off the flow returns automatically to the
bath function. If the flow pressure is insufficient, so
that the diverter not holds, a fixing device (pos. 13)
can be installed, please see page 7.
Temperature limitation
The temperature is limited by the safety check to
38°C. If a higher temperature is required, it is
possible to override the safety stop by depressing
the safety button.
English
To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
The mixer is equipped with non return valves and
filters. If the water flow drops the filters need to be
cleaned. For that purpous the mixer has to be
removed from the wall.
Attention!
The non return valves must be checked once a year.
Using the Ecomax in conjunction with
continuous flow heaters.
If fitting a hand shower remove the water limiter
from the shower.
Technical Data
Operating pressure:
Recommended operating pressure: 1 - 5 bars
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow tub spout:
Rate of flow shower outlet:
anti-pollution function
Spare parts
1
thermoelement
2
shut off unit
3
handle for thermoelement
3.1 cover for handle
4
handle for shut off unit
5
aerator cpl.
6
diverter knob
7
selector cpl.
8
connecting thread compl.
9
filter
10 escutcheon
11 s-unions
12 safety set for temperature control
13 diverter fixing device
max. 10 bars
16 bars
max. 80° C
65° C
58 l/min by 3 bars
18 l/min by 3 bars
96633000
92929000
96225000
96264000
97162000
97163000
96466000
97164000
97210000
96922000
96467000
94140000
95041000
97211000