2. OPERATION AND USE

Range between Easywave transmitters and receivers
Equipment using a remote control, such as TV, video and audio, does not suffer interference
from the Easywave transmitters. The Easywave transmitters need not be pointed at the receiver.
The range in buildings amounts to approx. 30m. In open fields, ranges of up to 100m are
possible. The transmitter range depends on the materials used in the building.
You can also use diagnosis unit 05-370 to determine the RF signal strength in a given envi-
ronment. The device detects all 868,3MHz signals. The reception quality of the transmitter
signal or the strength of the interfering signals present is indicated by 9 LEDs, allowing you
to determine whether the RF transmitter's range is sufficient.
brick, concrete
wood, plaster walls
reinforced concrete
enclosure in metall
loss: 20 to 40%
loss: 5 to 20%
loss: 40 to 90%
loss: 90 to 100%