en
16 | SCT 410 | Maintenance
4.6
Aligning the precision measuring bar
¶
Operate the positioning feet on the mobile base
plate to align the precision measuring bar by the
spirit levels.
!
For static windshield camera calibration, the
SCT 410 must be aligned by the roll angle and pitch
angle spirit levels.
2
1
4
Fig. 11:
Aligning the precision measuring bar
1 Precision measuring bar
2 Spirit level for roll angle
3 Spirit level for pitch angle
4 Positioning feet
5.
Maintenance
5.1
Cleaning
¶
Clean the SCT 410 only with neutral cleaning agents
and soft, lint-free cloths.
!
Coarse workshop rags and abrasive cleaning agents
may damage the SCT 410.
|
1 690 386 066
2017-08-11
3
2
3
4
4
5.2
Spare parts
Designation
Post with slide
Slide
Angle mounting bracket parts set
Clamp parts set
Mount for large calibration boards
Setting aid*
Wheel with fastening materials
Articulated foot with star knob screw
6.
Decommissioning
6.1
Changing location
¶
If the SCT 410 is handed over to another operator,
all the documentation included in the scope of deli-
very must be handed over with it.
¶
The SCT 410 must only be transported in the origi-
nal or equivalent packaging.
6.2
Service intervals
¶
Have the SCT 410 inspected once a year by autho-
rized customer service personnel.
6.3
Temporary shutdown
¶
Remove the precision measuring bar of the SCT 410
and store it safely.
6.4
Disposal and scrapping
¶
Dismantle the SCT 410, sort by materials and dispo-
se of in accordance with the applicable regulations.
7.
Technical Data
Property
Dimensions without precision
measuring bar, H x W x D
Dimensions with precision
measuring bar, H x W x D
Weight
Part number
1 690 381 125
1 690 382 280
1 690 381 229
1 690 381 233
1 690 381 157
1 690 381 210
1 690 381 208
1 690 381 149
Specification
1800 x 600 x 600 mm
1800 x 2000 x 600 mm
34 kg
Robert Bosch GmbH