ABNORMALITIES
The appliance restarts
numerous times even
without a utensil.
The utensil does not
emit air.
Fall of pressure in the
air tank.
Safety valve interven-
tion.
Ai r loss f rom the pres-
sure switch when ap-
pliance is off.
The appliance vibra-
tes and/or emits lots of
noise.
Frequent start-ups and
low performance.
20
CAUSE
Leakages from the air pipe,
utensil or pneumatic sy-
stem.
The tank is not pressurised. • Switch on the appliance and wait until the tank fills checking
Incorrect regulation of the
outlet pressure.
The utensil is damaged.
Leakages in the air pipe,
utensil or the pneumatic
system.
Pressure switch fault.
Unclean or worn return
valve.
Mechanical fault.
Unclean air filters.
A
Rev. 01_05_2017
SOLUTION
• Check that the pneumatic system is not damaged.
• Check that the air pipe and utensils are intact as well as the
connections.
the pressure of the relevant gauge.
• Check that the value displayed on the outlet pressure gauge
(A) is greater than 0 (zero) bar.
• Check that the utensil is intact and effective.
• Check that the pneumatic system is not damaged.
• Check that the air pipe and utensil are not damaged.
• Check that the appliance-air pipe and air pipe-utensil con-
nections are correct.
• Check that the condensate pump is securely closed (B).
• Contact an authorised Supplier.
• Contact an authorised Supplier.
• Contact an authorised Supplier.
• Carry out filter cleaning (see Paragraph 31).